More information:
 
Key features and benefits
 
Applications Library
 
 
Rosand capillary rheometers (毛细管流变仪)

您的位置主页实验室产品Rheometers (流变仪)Rosand capillary rheometers (毛细管流变仪)RH7 and RH10

RH7 & RH10 Capillary Rheometer (毛细管流变仪)

RH7 和RH10 : 强大的立式毛细管流变测量仪

Advanced, powerful floor standing capillary rheometers (毛细管流变仪) suitable for research and product development.

Since its launch, the Rosand RH7 has set new standards in research level capillary rheometry. Today, the Rosand RH7 is used in several hundred research laboratories around the world for a range of applications including polymers, foods, coatings and ceramics.

Malvern has continuously developed the original RH7 design and its operating software to produce a new generation of floor standing capillary units with market leading performance characteristics and capabilities. The RH7 and RH10 retain much of the robust 'H' frame design principle, which lies at the heart of the instruments' ability to operate under high loading conditions. A new digital drive system, gives the RH7 and the RH10 unsurpassed performance in terms of speed control, accuracy, and dynamic operating range. This new hardware is supported by the latest generation of 32 bit Windows™ based software, Flowmaster™, with many new experimental possibilities.

接下来?



   
 

 

RH7
RH10
Drive Force :

50kN

   
  100kN

   
Frame Stiffness:

  250kN

 
Drive Speed Maximum:

  600mm/min
   
    1,200mm/min

   
Dynamic Speed Range:

  400,000:1

 
Temperature Range:

  Ambient to 400ºC, 500ºC Option, twin bore barrel

 
    Low temperature cooling coil Option. Min temperature 10ºC, twin bore

 
    Low temperature liquid Nitrogeb Option. Min temperature -40ºC, single or twin bore.

 
Bore Diameter:

  15 mm Standard, 9.5, 2, 19 & 24 mm bore options

 
Barrel Bore Length:

  280mm

 
Barrel Material:

  Standard Nitrided Steel, Hastelloy or Stainless Steel options.

 
Pressure Transducer Ranges (PSI):

  30,000, 20,000, 10,000, 5,000, 1,500, 500

 
Pressure Transducer Accuracy:

  Better than 0.5%

 
Dies:

  Tungsten Carbide, precision +/- 5 micron

 
Die Diameter:

  0.5 to 3mm Standard, other diameters available to special order

 
Software analysis functions:

  Calculation of non-Newtonian Index  
    Calculation of Bagley Correction by Orifice Die and Extrapolation Methods

 
    Calculation of Rabinowitsch Corrections

 
    Hagenbach Correction for fluid inertia

 
    Cogswell (钝齿膨胀) Convergent Flow Model/Extensional Flow Assessment

 
    Extensive Plot and Print Options

 
    Data Export

 
Optional Software Module:

  Melt Fracture/Flow Instability Test Software

 
    Wall Slip Analysis Software

 
    Material Degradation/Thermal Stability Test Software

 
    Low Speed Degradation Test Software

 
    ETA-0 Analysis Software

 
    Stress Relaxation Test and Analysis Software

 

 

Laser Die Swell Options

     
Single Axis Laser Die Swell:

  Resolution 10 microns

 
Single Axis Twin Extrudate Laser Die Swell:

  Resolution 10 microns

 
Dual Axis Laser Die Swell:

  Resolution 10 microns

 
Single Axis High Resolution Laser Die Swell:

  Resolution 1 micron

 
Dual Axis High Resolution Laser Die Swell:   Resolution 1 micron


 

 

Die & Melt Cutters

     
Melt Cutter Single Strand:

  Die to cut distance : 100 to 160 mm

Die to Sensor distance (strand length) : 150 to 210 mm (50 mm below cut)

Recommended maximum shear rate (切割率) : 1000 s-1

 
Melt Cutter Twin Strand:

  Die to cut distance : 100 to 160 mm

Die to Sensor distance (strand length) : 150 to 210 mm (50 mm below cut)

Recommended maximum shear rate (切割率) : 1000 s-1

 

 

Hardware Accessories

     
Slot Die assembly:

  Slot Height 0.5 to 2.5 mm

 
PVT (Pressure, Volume Temperature) System

 

 
Haul Off/Melt Strength System:

 

Haul off motor/nip roller speed range : 2000 m/min max

Dynamic speed range > 100,000:1

Precision balance 2N capacity, 0.0001N resolution

Haul off die dimensions - 2.0mm (D) x 20mm (L) x 180° (Entrance angle)

 
Nitrogen purge

     